NorthStar 951x Betriebsanweisung

Seite von 206
Chapter 10 - Using Other Special Functions
951/952 Operator’s Manual Rev. B
Page 133
The word NEW indicates any alarm messages you haven’t pre-
viously displayed. 
The unit’s alarm types and descriptions are as follows:
Table 6: Alarm types and descriptions
Type
Description
Auto clear?
CLOSE
you’ve come within 900 feet of the arrival circle of 
the current waypoint (the arrival-circle radius is 
set from the 
ALARMS/ALARMS & BACK-
LIGHT 
screen)
YES, after 5 seconds
ARRIVE
you’ve entered the arrival circle of the current 
waypoint
YES, after 5 seconds
PASS
you’ve passed abeam of the waypoint, without 
entering the arrival circle
YES, after 5 seconds
CHANGING
switching to next leg of route (“NOW NAVIGAT-
ING TO . . .”)
YES, after 5 seconds
AVOIDANCE 
AREA
you’ve entered an avoidance-area circle 
NO, potential hazard 
ahead
ANCHOR DRAG
anchor is dragging beyond limit set on 
ALARMS/
ALARMS & BACKLIGHT
 screen
NO, requires immedi-
ate attention
NO LORAN FIX
no position fix received from external loran
YES, when condition 
clears
DGPS LOST
DGPS data time-out exceeded
NO GPS FIX
no position fix from GPS
NO LORAN 
DATA
communication failure with external loran receiver
NO GPS DATA
communication failure with GPS receiver module
POOR LORAN 
FIX
BLINK, CYCLE or LOW SNR detected at loran
CROSS-TRACK
LIMITS 
EXCEEDED
off-course in excess of limits set in 
CROSS 
TRACK ALARM
only when you’re within 
limits