Fortinet fortigate-5001a Hardwarehandbuch
FortiGate-5000 Series Hardware Guide
20
01-00000-0293-20060315
Connecting the FortiGate-5140 chassis to AC power using the FortiGate-5053 power converter tray
FortiGate-5140 chassis
The FortiGate-5053 power converter tray contains space for up to three
FortiGate-5140 power supplies. A FortiGate-5140 power supply converts AC
power to -48 VDC power. Each FortiGate-5140 power supply provides 1200W of
power.
FortiGate-5140 power supplies. A FortiGate-5140 power supply converts AC
power to -48 VDC power. Each FortiGate-5140 power supply provides 1200W of
power.
The FortiGate-5053 power converter tray uses 2 + 1 power supply redundancy.
If three FortiGate-5140 power supplies are installed in a FortiGate-5053 power
converter tray, the first two power supplies provide a total of 2400W (2 x 1200W)
of power. The third power supply is the redundant backup.
If three FortiGate-5140 power supplies are installed in a FortiGate-5053 power
converter tray, the first two power supplies provide a total of 2400W (2 x 1200W)
of power. The third power supply is the redundant backup.
The maximum power output for a FortiGate-5053 power converter tray with
FortiGate-5140 power supplies is 2400W; which can be achieved with two
FortiGate-5140 power supplies. If you need 2400W of power and power supply
redundancy, you can add a third FortiGate-5140 power supply.
FortiGate-5140 power supplies is 2400W; which can be achieved with two
FortiGate-5140 power supplies. If you need 2400W of power and power supply
redundancy, you can add a third FortiGate-5140 power supply.
Individual power requirements vary. If 1200W is enough power and redundancy is
not required, you require one FortiGate-5053 power converter tray and one
FortiGate-5140 power supply.
not required, you require one FortiGate-5053 power converter tray and one
FortiGate-5140 power supply.
If 1200W is sufficient but a redundant power supply is required, you can add a
second FortiGate-5140 power supply. This second power supply will also cover
power requirements between 1200 and 2400W. If you require redundant power
greater than 1200W you can add a third FortiGate-5140 power supply.
second FortiGate-5140 power supply. This second power supply will also cover
power requirements between 1200 and 2400W. If you require redundant power
greater than 1200W you can add a third FortiGate-5140 power supply.
Basic power requirements
To supply enough power for a FortiGate-5140 chassis with a total of 14 FortiGate
and FortiSwitch modules you require one FortiGate-5053 power converter tray
and two FortiGate-5140 power supplies (see
and FortiSwitch modules you require one FortiGate-5053 power converter tray
and two FortiGate-5140 power supplies (see
). The FortiGate-5140 power
supplies are installed in FortiGate-5053 slots 1 and 2. This configuration supplies
2400W of power to the FortiGate-5140 chassis.
2400W of power to the FortiGate-5140 chassis.
Figure 7: Non-redundant power for all FortiGate-5140 chassis slots
Note: If your will not be filling all of the FortiGate-5140 slots you may not need both
FortiGate-5140 power supplies.
FortiGate-5140 power supplies.
PWR
ACC
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
PWR
ACC
ST
A
IPM
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
5140
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
13
11
9
7
5
3
1
2
4
6
8
10
12
14
Alarms
Rst
Min.
3
2
1
2
1
Crit.
Maj.
Maj.
Link
Act
100
100
ETH 0
Stat.
Prim.
ShMC
Link
Act
100
100
ETH 0
Stat.
Sec.
ShMC
Slot 1
Slot 2
Slot 3
1 FortiGate-5053
power convertor tray
2 FortiGate-5140
power supplies
2 x 1200W = 2400W
1 FortiGate-5140
chassis