Fortinet fortigate-5001a Hardwarehandbuch
FortiGate-5001SX security system
Inserting a FortiGate-5001SX module into a chassis
FortiGate-5000 Series Hardware Guide
01-00000-0293-20060315
01-00000-0293-20060315
51
Figure 28: FortiGate-5001SX jumper positions
Inserting a FortiGate-5001SX module into a chassis
The following procedure describes how to correctly use the FortiGate-5001SX
mounting components shown in
mounting components shown in
to insert a FortiGate-5001SX module
into a FortiGate-5000 series chassis slot.
The FortiGate-5001SX module left extraction lever contacts to a hidden power
switch. The module must be fully installed in a chassis slot and this extraction
lever must be closed and locked for the FortiGate-5001SX module to receive
power and operate normally. If the FortiGate-5001SX module is not receiving
power, the IPM LED glows blue and all other LEDs remain off.
switch. The module must be fully installed in a chassis slot and this extraction
lever must be closed and locked for the FortiGate-5001SX module to receive
power and operate normally. If the FortiGate-5001SX module is not receiving
power, the IPM LED glows blue and all other LEDs remain off.
JP3
JP1
Front Faceplate
JP2
5050 and 5140 chassis
5020 chassis
Pins 2 and 3
Pins 1 and 2
JP3
JP3