Inserting a FortiGate-5001SX module into a chassis
FortiGate-5001SX security system
Figure 29: FortiGate-5001SX module mounting components
Before inserting the FortiGate-5001SX module in a chassis
Before installing the FortiGate-5001SX module in a chassis you must have 
installed RAM DIMMs and verified the JP3 jumper setting. You can also install the 
SPF transceivers before inserting the module.
Insertion procedure
FortiGate-5001SX modules are hot swappable. The procedure for inserting the 
FortiGate-5001SX module into a FortiGate-5000 series chassis slot is the same 
whether or not the FortiGate-5000 series chassis is powered on or not.
To insert a FortiGate-5001SX module into a FortiGate-5000 series chassis
Alignment Pin
Mounting
Knot
Locking
Screw
Left Extraction
Lever
Closed
Open
Alignment Pin
Mounting Knot
Locking
Screw
Left Extraction
Lever
Alignment Pin
Mounting Knot
Switch
Contact
Power
Switch
Locking
Screw
Left Extraction
Lever
!
Caution: Do not carry the FortiGate-5001SX module by holding the extraction levers. 
When inserting or removing the FortiGate-5001SX module from a chassis slot, handle the 
module by the front panel. The extraction levers are designed for positioning and locking 
the FortiGate-5001SX module into a slot in a chassis only and should not be used for 
handling the module. If the extraction levers become bent or damaged the 
FortiGate-5001SX module may not align correctly in the chassis slot and the left extraction 
lever may not activate the power switch.