Fortinet fortigate-5001a Hardwarehandbuch

Seite von 97
FortiGate-5000 Series   Hardware Guide
70
01-00000-0293-20060315
Troubleshooting
FortiGate-5001FA2 security system
5
Open the left and right extraction levers to their fully open positions.
Opening the extraction levers slides the module a short distance out of the slot, 
disconnecting the module from the chassis backplane.
The IPM LED turns blue. All other LEDs turn off.
6
Pull the module about half way out.
All LEDs turn off.
7
Turn both extraction levers to their fully-closed positions.
When the extraction levers are fully-closed they lock into place.
8
Carefully slide the module completely out of the slot.
Troubleshooting
This section describes the following troubleshooting topics:
FortiGate-5001FA2 does not startup
Positioning of FortiGate-5001FA2 extraction levers, the presence or absence of a 
functioning shelf manager, incorrect jumper settings and firmware problems may 
all prevent a FortiGate-5001FA2 module for starting up correctly. This section 
describes how to find and fix each of these problems.
All chassis: left extraction lever not contacting power switch
The left extraction lever activates the FortiGate-5001FA2 module power switch.
Open
Fully Open
Alignment Pin
Extraction
Lever
Extraction
Lever
Close
Fully Closed
and Locked
Alignment Pin
Alignment Pin
Extraction
Lever