Fortinet fortigate-5001a Hardwarehandbuch

Seite von 97
FortiGate-5002FB2 security system 
Troubleshooting
FortiGate-5000 Series   Hardware Guide
01-00000-0293-20060315
83
FortiGate-5002FB2 does not startup
Positioning of FortiGate-5002FB2 extraction levers may prevent a 
FortiGate-5002FB2 module for starting up correctly. 
All chassis: left extraction lever not contacting power switch
The left extraction lever activates the FortiGate-5002FB2 module power switch.
Figure 39: Location of FortiGate-5002FB2 power switch
If the left extraction lever is damaged or positioned incorrectly the 
FortiGate-5002FB2 module does not receive power and will not start up. Make 
sure the left extraction lever is correctly aligned, fully inserted and locked. 
Sometimes you may have to make small adjustments to the extraction lever to 
achieve contact with the switch.
All chassis: Firmware problem
If the FortiGate-5002FB2 module power switch is connected and the 
FortiGate-5002FB2 still does not start up, the problem could be with FortiOS. 
Connect to the FortiGate-5002FB2 console and try cycling the power to the 
module. If the BIOS starts up, interrupt the BIOS startup and install a new 
firmware image. For details about installing a new firmware image, see the 
If this does not solve the problem, contact Fortinet Technical Support.
Left Extraction
Lever
Extraction Lever
Lock
Switch
Contact
Power
Switch