Hitachi ed-pj32 Benutzerhandbuch

Seite von 59
55
ENGLISH
Troubleshooting
Regarding the indicator lamps (continued)
• When the interior portion has become overheated, for safety 
purposes, the power source is automatically turned off, and the indicator lamps 
may also be turned off. In such a case, press the “” (OFF) side of the power 
switch, and wait at least 45 minutes. After the projector has sufficiently cooled 
down, please make confirmation of the attachment state of the lamp and lamp 
cover, and then turn the power on again.
NOTE
POWER 
indicator
LAMP 
indicator
TEMP 
indicator
Description
Blinking 
In 
Red
 
or 
Lighting 
In 
Red
Turned 
off
Blinking 
In 
Red
The cooling fan is not operating.
Please turn the power off, and allow the projector to 
cool down at least 20 minutes. After the projector has 
sufficiently cooled down, please make confirmation 
that no foreign matter has become caught in the fan, 
etc., and then turn the power on again.
If the same indication is displayed after the remedy, 
please contact your dealer or service company.
Blinking 
In 
Red
 
or 
Lighting 
In 
Red
Turned 
off
Lighting 
In 
Red
There is a possibility that the interior portion  
has become heated.
Please turn the power off, and allow the projector to 
cool down at least 20 minutes. After the projector has 
sufficiently cooled down, please make confirmation of 
the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
• Is the projector used at a highland? Please set FAN 
SPEED of the SERVICE item in the OPTION menu to 
HIGH, only when the projector is used at a highland. 
(45)
Lighting 
In 
Green
Alternative
blinking in 
Red
There is a possibility that the interior portion  
has become overcooled.
Please use the projector within the usage temperature 
parameters (5°C to 35°C). After the remedy, reset the 
power to ON.
Lighting 
In 
Green
Simultaneous
blinking in 
Red
It is time to clean the air filter.
Please immediately turn the power off, and clean or 
change the air filter referring to the section “Air Filter”. 
After cleaning or changing the air filter, please be sure 
to reset the filter timer. After the remedy, reset the 
power to ON.