6
Drop In Procedure
These units are intended for indoor use only.  A room 
temperature of not more than 86°F (30°C) is recommended.  
Reinforce the counter as necessary to provide maximum 
loading.
Unit requires that the sides and bottom are not 
any closer than 3” to any combustible material.
The counter cut-out sizes and power requirements are shown 
on pages 3-5.  A gasket is installed in the flange of each unit.  
The weight of the unit on the gasket forms a seal preventing 
liquids from seeping into the cut-out opening.
Louvers
Self-contained refrigerated units (N8100, N800 and N800G 
Series) require airflow to the compressor.  A 13” x 5” louver 
is (33 cm x63.5 cm) provided by Delfield and must be installed 
in the counter in front of the condenser.  See specifications on 
page 3 for louver cutout dimensions.  The rear must have an 
opening to permit removal of heated air.  The opening must be 
at least 8” x 11”, a total of 88 square inches (0.3 cm x 7.9 cm, 
a total of 566 square centimeters).
Plumbing
The unit’s drain must have an outlet to an appropriate drainage 
area or container.  N800 series have 1/” drain and N800G 
series have 3/4” drain located on end/center.  The 1” diameter 
drain on N8000, N8100, 8100FA and 8100EF Series units is 
shipped loose and must be connected during installation.
Moisture collecting from improper drainage 
can create a slippery surface on the floor 
and a hazard to employees.  It is the owner’s  
responsibility to provide a container or outlet 
for drainage.
Some N8000, N8000N, N8100B and N8100NB 
may have poyethylene insulation in the drain 
hole.  This can easily be cut out without 
any contact or damage to the units interior 
insulation or refrigeration lines.
Electrical connection
Refer to the amperage data on pages 3-5, the serial tag or 
your local code to be sure the unit is connected to the proper 
power source. A protected circuit of the correct voltage and 
amperage must be run for connection of the line cord.
Some units have an “ON/OFF” switch located behind the 
louvered panel in the machine compartment. Simply turn the 
switch to “ON” to begin operation.
Some units have an “OFF” position on the switch which is  
located behind the louvered panel in the machine compart-
ment. Simply turn the dial to begin operation.
The unit must be disconnected from the 
power source whenever performing service or 
maintenance functions.
Never operate the unit without the louvered 
panel in place!
CAUTION
Installation N8000, N8000N, N8100B, N8100NB, N8200, N8200G, N8100-FA & 8100-EF Series
D A N G E R
Drop In Procedure
These units are intended for indoor use only.  Reinforce the 
counter as necessary to provide maximum loading.
Unit requires that the sides and bottom are not 
any closer than 3” to any combustible material.
The counter cut-out sizes and power requirements are shown 
on pages 3-5.   A gasket is installed in the flange of each unit.  
The weight of the unit on the gasket forms a seal preventing 
liquids from seeping into the cut-out opening.
N8700-D Series pans should be installed with the drains at the
back, away from the operator’s sides. N8700N Series have
drains located in the front - operator side.
The controls on N8700-D and N8800 Series units are mounted 
in a control panel, designed to be installed at a “remote” 
location.  The control panel should be installed so that the 
indicator light for each control is above the control.  N8700 & 
N8700N Series units have 48” (11.9cm) of conduit and N8800 
Series units have 4” (61.0cm) of conduit between the pans and 
the remote control panel to facilitate this installation.
Plumbing
N8700-D and N8700N Plumbing: Unit is equipped with 1/” 
drains, (one per well located in right rear corner 1/” female 
N.P.T.) manifold and 1/” gate valve.
N8800 Plumbing: Well is sloped to a 1.00” female N.P.T. 
stainless steel drain.
Moisture collecting from improper drainage 
can create a slippery surface on the floor 
and a hazard to employees.  It is the owner’s 
and operator’s responsibility to provide a 
container or outlet for drainage.
Electrical connection
Refer to the amperage data on pages 3-5, the serial tag or 
your local code to be sure the unit is connected to the proper 
power source. 
The unit must be disconnected from the 
power source whenever performing service 
or maintenance functions.
CAUTION
D A N G E R
Installation N8700D, N8700N, & N8800 Series