LXE mx7 Verweisanleitung

Seite von 376
LXE Scanner Wedge 
329 
E-EQ-MX7RG-H 
 
MX7 Reference Guide 
Factory Default Settings 
Factory Default Settings 
Main 
Port 1 
Internal 
Port 2 
Disabled 
Port 3 
Disabled 
Send key messages (WEDGE) 
Enabled 
Enable Internal Scanner 
Sound 
Enabled 
Good Scan Vibration 
Disabled / Long 
Bad Scan Vibration 
Disabled / Long 
COM1 Port (external serial port) 
Baud Rate 
9600 
Stop Bits 
Parity None 
Data Bits 
Barcode 
Use Advanced Barcode Processing 
Disabled 
   
   
 
Scanner Control Panels 
If “Send Key Messages …” is checked any data scan is converted to keystrokes and sent to the 
active window. When this box is not checked, the application will need to use the set of LXE 
Scanner APIs to retrieve the data from the scanner driver. Note that this latter method is 
significantly faster than using “Wedge”. Even if Send Key Messages is enabled (key mode), the 
data is still available using the scanner APIs (block mode). 
Disable “Enable Internal Scanner Sound” when you want an application, not the scan engine or 
the CE operating system, to control scanner audible notifications. Adjust the settings and tap the 
OK box to save the changes. This change takes effect immediately.