LXE mx7 Verweisanleitung

Seite von 376
MX7 Cold Storage 
69 
E-EQ-MX7RG-H 
 
MX7 Reference Guide 
The touchscreen heating elements and scanner aperture heating elements may be visible when the 
MX7 is tilted slightly. No user interaction is required to turn the heatings elements on/off. Stylus 
taps on the touchscreen function normally. 
Recharging Batteries 
The Cold Storage battery pack can be recharged to full capacity while in an MX7CS connected to 
an external power source and also while the Cold Storage battery pack is inserted in the charging 
bay in a powered MX7 desk cradle. The battery pack temperature must be above 10°C (50°F) 
before re-charging can begin. 
Battery packs in the MX7 Multi-charger begin charging when the battery pack temperature is 
between 10°C (50°F) and +40°C (100°F). 
To charge the Cold Storage battery pack to full capacity, the MX7 Multi-charger firmware must 
be at V1.07 or greater. The firmware version is noted on the multi-charger label on the bottom of 
the device.  
If your multi-charger firmware needs to be upgraded, please contact your LXE representative.  
The multi-charger and AC adapter are not designed to operate in a freezer or cold storage 
environment. Please refer to the MX7 Multi-charger User’s Guide for instruction and technical 
information. 
Hot-swapping the Cold Storage Battery 
The MX7CS, and a charged 2.5V SuperCap backup battery, retains data during a main battery 
hot-swap at -30°C (-22°F) for at least 90 seconds. The temperature of the fully charged 
replacement Cold Storage main battery must be +10°C (14°F), or above. 
Normal Operation Temperature Ranges 
• 
In the freezer where the temperature ranges between –30°C to -18°C (-22°F to 0°F). 
• 
In the loading dock where temperature ranges between 0°C to 5°C (32°F to 41°F)with the 
relative humidity at 65% 
• 
Moving between the freezer and a loading/unloading area where the temperature 
transitions from -30°C to 5°C (-22°F to 41°F)