LXE mx6 Verweisanleitung

Seite von 338
206 
Power Tools EZConfig Utilities 
MX6 Reference Guide 
 
E-EQ-MX6RG-E 
Key Value 
Description 
AimerDelayALR 
500 
Similar to AimerDelay, but for ALR mode only 
Trigger 42 
Default: 42 
(On/Scan Key) 
Sets the key used by ScanDemo to initiate a 
scan/decode. The key is registered as a system hot 
key, it cannot be registered as a hot key by any 
other applications.  
ScanTimeout 9000 
Default: 2000  
(2 seconds) 
Specifies the decode time out in 1/1000th seconds. 
If a barcode is not decoded within the specified 
timeout period an audio and visual notification 
will indicate that an error occurred. 
ScanAbort 
Specifes the behavior of the decoder upon release 
of the trigger key. 
0 = The decoder will scan as long as specified by 
the ScanTimeout parameter 
1 = Releasing the trigger key will cause the 
decoder to stop scanning. 
ScanInterval 
Time interval between scanning attempts 
(milliseconds), when in AutoScan mode. 
ScanMode 
Specifies the decode mode. If 1, the decoder is in 
normal mode. If 2, the decoder works in ALD 
(Aggressive Linear Decode) mode. 
LinearRange 3 
Default: 3 
Specifies the linear search range to be used while 
in ALD mode. The range is 1 to 6. A value of 1 
indicates a tight vertical range near the aimer. A 
value of 6 indicates a vertical range of the entire 
height of the imager.  
PrintWeight 
1-7: Sets the decoder's PrintWeight parameter: 
adjusts the way the decoder reads Matrix symbols. 
If the image engine will be seeing consistently 
heavily printed Matrix symbols, a print weight of 
6 or 7 may improve reading performance. 
ReplaceCRwithCRLF  0 
0/1: If set to 1, replaces the carriage return (13) in 
the decoded data with carriage return and line feed 
(13,10). 
0=Disable 
1=Enable 
GoodScanWav 
Default=”” 
Specifies a wave file to be played on a successful 
decode/data reception. The wave file should be an 
8 bit, 11KHz, mono, PCM file. If no wave file is 
specified, the default beep will be utilized. Use the 
‘sound’ setting to enable and disable audio 
notification. NOTE: The Window's “Good 
Decode” sound defined in the control panel or the 
GoodScanFreq parameter take precedence over 
this option, if defined.