LXE mx6 Verweisanleitung

Seite von 338
Using the Multicharger 
309 
E-EQ-MX6RG-E 
 
MX6 Reference Guide 
Charging 
As soon as a battery pack is placed in any slot, charging begins and the Status LED illuminates.  
Green
  Charge cycle completed and battery is ready for use. 
Orange
  Charge cycle is progressing. 
Red
 
Battery or charge slot encountered an error during the recent charge cycle. 
Analyzing 
Note: 
 Because the multicharger is accumulating battery pack information during the entire 
Analyze cycle, it is important not to remove the battery until the cycle has been 
completed. 
Insert a battery into the right-most slot (the slot next to the Analyze button).  
Press the Analyze button. 
The Analyze cycle begins. Only the battery in the Charge/Analyze slot is analyzed. 
In an Analyze cycle, batteries are completely discharged and then recharged to capacity. The 
indicator LEDs display just what that capacity is at the end of the cycle. The battery is completely 
reset and re-calibrated. Resetting and calibrating batteries on a regular basis can provide longer 
and more consistent performance from those batteries. 
The length of time it takes for a battery to run through the complete Analyze cycle varies depends 
on initial state of the battery. 
Minimum time is 8 hours, maximum time is 12 hours. 
The Charge/Analyze slot also contains a Status LED in the upper, left corner of the slot. When this 
slot is used for regular charging, this LED operates in the usual manner. 
Battery Capacity Indicator LEDs 
The Battery Capacity Indicator LEDs are located along the right side of the Charge/Analyze slot. 
The LEDs illuminate after the completion of the Analyze cycle. Upon the completion of the final 
charge, the LEDs display the measured capacity of the battery. Battery capacity is displayed as a 
percentage of measured capacity/rated capacity. Each LED equates to 10% battery capacity. 
Analyzer Slot Status LED 
When this slot is being used to analyze a battery, the Status LED functions as follows: 
Solid Green  
Has completed the Analyze cycle. 
Flashing Orange   Is being analyzed. 
Solid Red  
Encountered an error during the Analyze cycle.