LXE mx6 Verweisanleitung

Seite von 338
310 Technical 
Specifications 
MX6 Reference Guide 
 
E-EQ-MX6RG-E 
Technical Specifications 
Operating Temperature 
14°F to 122°F (-10°C to 50°C)  
Storage Temperature 
-4°F to 158°F (-20°C to 70°C) 
Charging Temperature 
32°F to 113°F (0°C to 45°C) 
Weight 
18 oz (510 g) 
Dimensions 
Length 11.7 in x Width 5.2 in x Height 1.5 in  
Length 29.7 cm x Width 13.2 cm x Height 3.8 cm 
Capacity 
1 to 4 battery packs 
Power Supply Input 
90-265V, 47-63Hz 
Power Supply Output 
12VDC, 3A 
Input Connection 
2 position IEC 320-C8 
Charging Mode: Standard 
100% charge in 4 hours 
Charging Mode: Analysis 
Charges/discharges/resets/calibrates battery in 14 hours 
 
Troubleshooting 
Problem  
Issue 
The Charging LED does not 
come on when a battery pack is 
locked into a slot. 
Check the AC power connection; make sure the power 
switch is ON and the battery pack is properly seated. 
The red status LED comes on 
during charging. 
Try to charge the battery in one of the other charging slots. 
If the red Status LED comes on again, then the problem is 
associated with the battery pack. If the red status stays 
with the charging slot, the problem is associated with the 
charging circuitry. 
The red status LED remains on 
without a battery in the charging 
slot. 
An error occurred during the self-diagnostic test for that 
particular charging slot. Contact LXE Technical Services. 
‘