External Power Supply, Optional 
VX7 User’s Guide 
E-EQ-VX7OGWW-H 
External Power Supply, Optional 
The LXE-approved AC Power Adapter is only intended for use in a 25ºC (77ºF) maximum 
ambient temperature environment. 
2
1
 
1.  AC Input Cable 
(US only) 
2.  DC Output Cable
 
Figure 61  Optional Power Configuration 
In North America, this unit is intended for use with a UL Listed ITE power supply with 
output rated 12 – 80 VDC, minimum 75W.  Outside North America, this unit is intended for 
use with an IEC certified ITE power supply with output rated 12 – 80 VDC, minimum 75W. 
The external power supply may be connected to either a 120V, 60Hz supply or, outside North 
America, to a 230V, 50Hz supply, using the appropriate detachable cordset. In all cases, connect 
to a properly grounded source of supply provided with maximum 15 Amp overcurrent protection 
(10 Amp for 230V circuits). 
How To:  Connect External Power Supply 
1. 
Turn the VX7 off. 
2. 
Connect the detachable cordset provided by LXE (US only, all others must provide 
their own cable) to the external power supply (IEC 320 connector). 
3. 
Plug cordset into appropriate, grounded, electrical supply receptacle (AC mains). 
4. 
Connect the watertight connector end to the VX7’s Power Connector by aligning the 
connector pins to the power connector; push down on the watertight connector and 
twist it to fasten securely. 
5. 