30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
(For 3 or 4 Wire, 60 Hz. Systems)
3
2a. Models with Factory Connected Power Supply
Cord
NOTE: Some models may have a factory
installed three (3) conductor Power Supply Cord.
Mobile home installations, new branch circuit installations
(1996NEC) or areas where Local Codes do not permit
grounding through neutral require a four (4) conductor
power supply cord kit rated at 125/250 volts minimum and
marked for use with ranges.
See Range Connection Opening Size Chart  (Figs. 9 & 10)
for cord kit ampere rating information. Terminals on end of
wires must be either closed loop or open-end spade lugs
with upturned ends.
This appliance may be connected by means of a power
supply cord. Only a power supply cord kit rated at 125/250
volts minimum, and marked for use with ranges shall be
used. See Fig. 10 for cord kit ampere rating information.
Cord must have either three (3) or four (4) conductors
(See Fig. 8). Terminals on end of wires must be either
closed loop or open-end spade lugs with upturned ends.
Cord must have strain relief properly installed. See Steps
4a. for 4-Wire or 4b. for 3-Wire connections.
3. ELECTRICAL CONNECTION TO RANGE.
The Rear Access Cover must be removed (Fig 9). To
remove, loosen center screw (one screw) and remove
cover. The terminal block will then be accessible.
NOTE:  Range is shipped from factory with 1-3/8" dia. hole as
shown. To use either 7/8" dia. hole or 1-1/8" dia. knockouts refer
to Fig. 9.
2b. MODELS REQUIRING POWER SUPPLY CORD KIT.
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF
AN INCORRECT SIZE RANGE CORD KIT IS USED, THE
INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED
OR STRAIN RELIEF BRACKET IS DISCARDED.
2. ELECTRICAL CONNECTION REQUIREMENTS - This
appliance must be properly installed and grounded by a
qualified technician in accordance with the National
Electrical Code ANSI/NFPA No. 70 -- latest edition -- and
Local Electrical Code requirements.
This appliance may be connected by means of "Permanent
Wiring" or "Power Supply Cord Kit."
When installing Permanent Wiring, do not leave excess
wire in range compartment. Excess wire in the range
compartment may not allow the Rear Access Cover to be
replaced properly and could create a potential electrical
hazard if wires become pinched. Connect only as
instructed under "PERMANENT WIRE CONNECTIONS" in
Step 4c.  When using flexible conduit or range cable use
flex connector or range cable strain relief (See Fig. 11).
may be used in wood or concrete material.  Use a 5/16"
nut-driver or flat head screwdriver to secure the bracket in
place (See Fig. 6).
1c. Level and Position Range - Level range by adjusting
the (4) leveling legs with a wrench. NOTE: A minimum
clearance of 1/8" is required between the bottom of the
range and the leveling leg to allow room for the bracket.
Use a spirit level to check your adjustments.  Slide range
back into position (See Fig. 7).
Visually check that rear leveling leg is inserted into and
fully secured by the Anti-Tip Bracket by removing lower
panel or storage drawer. For models with a Warmer
Drawer or broiler compartment, grasp the top rear edge of
the range and carefully attempt to tilt it forward.
3 & 4 - Wire electrical wall Receptacle types &
recommended mounting orientation on wall
Fig. 7
Fig. 8
Fig. 9
Rear
Access
Cover
Fig. 10