Frigidaire fefs66dsf Installationsanweisungen

Seite von 6
30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
(For 3 or 4 Wire, 60 Hz. Systems)
4
or 4B. POWER CORD CONNECTIONS
(3-Wire Connection Instructions . For existing installations ONLY -
Refer to Fig. 13).
1.
Follow the manufacturer’s installation instructions supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).
2.
Insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).
IMPORTANT NOTE:  DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed.
3.
Make sure all connections are tightened securely and replace the
rear access cover (See Fig. 9).
(4-Wire Connection Instructions - Refer to Fig.12)
Before wiring the range review the suggested power source location
drawing in Fig. 3. If connecting to a 4-Wire electrical system (new
branch-circuit or mobile home requires 4-Wire connection):
1.
Follow the manufacturer’s installation instructions supplied with
the strain relief and install (Also see Figs. 9, 10 & 11).
2.
Insert the end connectors for Line 1, Line 2 and Neutral and
tighten securely to the terminal block.
IMPORTANT NOTE:  DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if
these 3 nuts are loosened or removed.
3.
You must disconnect the ground strap.  Remove the factory
installed ground screw & plate to release the copper ground strap
from the frame of the appliance. Cut and discard the copper
ground strap & plate. KEEP the ground screw.
4.
Connect the ground wire (Green) lead with the eyelet to the
frame of the appliance with the ground screw using the same
hole in the frame where the ground screw was originally installed
(See Fig. 12).
5.
Make sure all screws are tightened securely and replace the rear
access cover (See Fig. 9).
Grounding Instructions (3-Wire Connections only):
A ground strap is installed on this range which connects the center
terminal of the terminal block (Neutral) to the range chassis. The
ground strap is connected to the range by the center, lowest screw
(See Fig. 13). The ground strap must not be removed unless
National, State or Local Codes do not permit use of a ground strap.
NOTE:  If the ground strap is removed for any reason, a separate
ground wire must be connected to the separate ground screw
attached to the range chassis and to an adequate ground source.
Fig. 11
4A. POWER CORD CONNECTIONS
Fig. 13
Fig. 12