Panasonic aj-sdx900 Benutzerhandbuch

Seite von 102
78
Chapter 7  Menu description tables
TAKE TOTAL TIME
NONE
5day
For setting the time required for shooting.
Select a setting from NONE (shooting
continues until it is stopped manually) to
5DAY (5 days).
NEWS REC MODE
(AJ-YA903G not
installed)
OFF
0.2SEC
2.0SEC
For setting the NEWS REC time.
Item
Variable
range
Remarks
INTERVAL REC
MODE
ON
ONE SHOT
OFF
For setting the INTERVAL REC function.
ON (MEMORY):
Interval recording is possible in single-
frame units using memory (AJ-YA903G
installed).
The recording time is 2 seconds or more
for interval recording when memory is not
used (AJ-YA903G not installed).
ONE SHOT:
Recording is performed only once for the
time set in the REC TIME item, after which
it stops.
OFF: Interval recording is not performed.
REC TIME
00s01f
59s29f
For setting the recording time (for one cut).
The shortest possible recording time when the
memory is not used is 2 seconds.
<Note>
In the 24P or 24PA mode, operation is
performed with the recording time rounded off
to the nearest 5-frame increment.  The
shortest recording operation is 5 frames (with
the setting of not more than 9 frames).
PAUSE TIME
00h00m00s01f
00h04m59s29f
23h59m59s29f
For setting the recording pause time.
<Note>
In the 24P or 24PA mode, operation is
performed with the recording time rounded off
to the nearest 5-frame increment.  When the
AJ-YA903G board is installed, the shortest
recording operation is 5 frames (with the
setting of not more than 9 frames); when it is
not installed, the shortest recording operation
is 4 seconds (with the setting of not more than
4 seconds/4 frames).
TOTAL REC TIME
00m00s01f
90m59s29f
OVER 100min
NONE
For displaying the total recording time.  The
setting for this time cannot be changed.
The total time yielded by adding the REC
TIME, PAUSE TIME and TOTAL TAKE TIME
is displayed.
<Note>
In the 24P or 24PA mode, operation is
performed with the recording time rounded off
to the nearest 5-frame increment.  Displayed
at the TAKE TOTAL TIME is the value based
on actual operation in 5-frame increments.
AUDIO REC
OFF
ON
For setting whether or not to record the
sound.
PRE REC MODE
(AJ-YA903G
installed)
OFF
0SEC
7SEC
15SEC
For setting the PRE REC function.
OFF:
The PRE REC function is not
operable.
0-15SEC: The duration for which pre-
recording can be performed after
the REC START button is pressed
is set here.
7-2-3
REC FUNCTION
START DELAY
0SEC
10SEC
For setting the time taken until recording is to
start after the REC START button is pressed
in the INTERVAL REC mode.
SDI EDH
ON
OFF
For setting whether or not to add the error
detection flags to the SDI output.
Item
Variable
range
Remarks
P.OFF GPS DATA
HOLD
CLEAR
For selecting whether or not to hold the UMID
GPS position information while the power is
off and record the information as the data still
held as the previous value until another
measurement can be taken after the power is
next turned on.
HOLD: The data is held and recorded.
CLEAR: The data is cleared at the same time
as the power is turned off, and all
zeros (no information) are recorded
from the time the power is turned on
until the measurement is next taken.
COMPONENT OUT
M2
BETACAM
OFF
For selecting whether to conserve the power
of the component output to peripheral units.
M2:
The power is output at the M2 level.
BETACAM: The power is output at the
BETACAM level.
OFF:
Output stops during power save.
(Note that this setting is forced ON
if a camera adapter is connected
and a tally signal is detected from
pin 26.  Otherwise it is OFF.)
26PIN CONTROL
OFF
BOTH
For setting the 26-pin control mode.
OFF:
Only the unit is controlled.  (No 26-pin
control).
BOTH: Control over both the unit and 26-pin
connector is exercised.  The tally LED
indicates the status of the 26-pin tally
signal.  (The unit’s recording can be
set using the REC TALLY item on the
SYSTEM MODE menu.)
SDI METADATA
ON
OFF
For setting whether or not to output the
metadata to SDI.
26PIN CTL
DEFAULT
NORMAL
SPECIAL
For selecting the portable to be used (for
switching the VTR/SS initial status).
NORMAL: Initially “L”: AJ-D92
SPECIAL: Initially “H”
7-2-2
OPTION MODE