1. Part of metal ground strap must be cut out and removed.
2. Use Phillips screwdriver to remove the ground-link screw 
from the back of the range. Save the ground-link screw and 
the end of the ground-link under the screw.
3. Pull the conduit through the strain relief on cord/conduit plate 
on bottom of range. Allow enough slack to easily attach 
wiring to the terminal block.
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2 
(red) wires. Loosen (do not remove) the set screw on the front 
of the terminal lug and insert exposed wire end through 
bottom of terminal lugs. Securely tighten set screw to torque 
shown in following Bare Wire Torque Specifications chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
5. Use Phillips screwdriver to connect the bare (green) ground 
wire to the range with the ground-link screw. The ground wire 
must be attached first and must not contact any other 
terminal.
6. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the 10–32 hex nuts.
7. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
A. Metal ground strap
B. Discard
C. Ground-link screw
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
E. Neutral (white) wire
F. Line 1 (black) wire
G. Bare (green) ground wire
A
B
C
A
B
C
D
E
F
G
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A. 10–32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link screw
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
A
B
C
D
E
B
A
G
E
C
D
F