Whirlpool GY397LXU Installationsanweisungen

Seite von 20
12
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground 
conductor to neutral supply wire.
1. Pull the conduit through the hole and conduit plate on bottom 
of range. Allow enough slack to easily attach the wiring to the 
terminal block.
2. Attach terminal lugs to line 1 (black), bare (green) ground, 
and line 2 (red) wires. Loosen (do not remove) the set screw 
on the front of the terminal lug and insert exposed wire end 
through bottom of terminal lugs. Securely tighten set screw to 
torque shown in following Bare Wire Torque Specifications 
chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use 
³⁄₈" nut driver to connect the bare (green) ground wire to 
the center terminal block post with one of the 10–32 hex nuts.
4. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
Verify Anti-Tip Bracket Location
1. Making sure the anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to floor or 
wall.
Slide range back so rear range foot is engaged with
anti-tip bracket.
Level Range
1. Place rack in oven. Place level on rack and check levelness of 
range, first side to side; then front to back.
2. If range is not level, pull range forward until rear leveling leg is 
removed from the anti-tip bracket.
3. Use wrench to adjust leveling legs up or down until range is 
level. Push range back into position.
4. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking conditions.
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A
B
C
D
E
F
A
B
C
D
E
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug
B
F
A
E
D
C