Bunn FMD-3 Betriebsanweisung

Seite von 42
23
P1449
FIG. 12 DISPENSE SWITCH TERMINALS
LEFT
CENTER
RIGHT
BLK
RED/BLK
BLK
RED/WHI
BLK
RED
ORN
BLU/WHI
ORN
BLK/WHI
ORN
BLU/BLK
DISPENSE SWITCH
P1631
SERVICE (cont.)
Location:
 
The  dispense  switches  are  located  on  the  lower 
outside of the dispenser door.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Open the dispenser door and remove the bottom 
door cover.
3.  Disconnect the wires from the door interconnect wir-
ing harness to the dispense switch to be tested.
4.  Check for voltage across the black and red/black 
wires  for  the  right  dispense  switch,  black  and 
red/white wires for the center dispense switch or 
the black and red wires for the left dispense switch 
from the door interconnect wiring harness. Connect 
the dispenser to the power supply. The indication 
must be:
 
a) 120 volts ac for two wire 120 volt models, 120/208 
volt and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
5.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the dispenser wiring harness.
6.  With  a  voltmeter,  check  the  voltage  across  the 
blue/black (+) and orange (-) wires for the right 
dispense  switch,  black/white  (+)  and  orange  (-) 
wires for the center dispense switch, or blue/white 
(+) and orange (-) for the left dispense switch from 
the door interconnect wiring harness. Connect the 
dispenser to the power source. The indication must 
be +5 volts dc.
If voltage is present as described, proceed to #7.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the dispenser wiring harness.
7.  Check for continuity across the terminals (top right 
to top left; bottom right to bottom left) of the dis-
pense switch with the switch in the “ON” position. 
Continuity must not be present when the switch is 
in the “OFF” (released) position.
If  continuity  is  present  as  described,  reconnect  the 
connector to the door interconnect wiring harness, the 
switch is operating properly.
If continuity is not present as described, replace the 
switch.
Removal and Replacement:
1.  Open the dispenser door.
2.  Remove the five #6-32 screws securing the bottom 
door cover and remove cover.
3.  Disconnect the wires on the dispense switch to be 
removed from the door interconnect wiring har-
ness.
4.   Compress the clips inside the door on the dispense 
switch  and  gently  push  the  switch  through  the 
opening.
5.  Push new switch into the opening and spread the 
clips to hold the switch in the door.
6.  Reconnect the wires to the dispense switch from 
door interconnect wiring harness.
7.   Reinstall the door bottom cover using five #6-32 
screws.
8.  Refer to Fig. 12 when reinstalling wires. 
FIG.11 DISPENSE SWITCH
29170  090407