FAN
FIG. 13 FAN
P1436
Location:
 
The fan is located inside the dispenser housing on 
the right rear of the dispenser base plate.
Test Procedures:
1.  Disconnect  the  dispenser  from  the  power 
source.
2.  Disconnect the black and white wires from the  
fan terminals.
3.  With  a  voltmeter,  check  the  voltage  across  the 
black and white wires. Connect the dispenser to 
the power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt, three wire 
120/208 volt and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
If voltage is present as described, replace the fan.
If voltage is not present as described, refer to Wiring 
Diagrams and check the dispenser wiring harness.
SERVICE (cont.)
29170 090407
Removal and Replacement:
1.  Disconnect the vacuum hose from the fan.
2.  Remove the two #8-32 locking screws securing 
the fan to the dispenser housing base plate.
3.  Disconnect the wires from the fan terminals and 
discard the fan
4.   Refer to Fig.14 and connect the wires to the new 
fan.
5.  Install new fan through the rear access hole and 
secure to the dispenser housing base plate using 
two #8-32 locking screws.
6.  Reconnect the vacuum hose to the fan.
BLK from Main
WiringHarness
WHI from Main Wiring Harness
FIG. 14 FAN TERMINALS
P1507