Bunn FMD-3 Betriebsanweisung

Seite von 42
39
SERVICE (cont.)
FIG. 38 TANK HEATER SWITCH TERMINALS
P1208
BLK from Main Harness
(Mechanical Thermostat)
WHI/BRN from Main Harness
(Electronic Thermostat)
BLK from Main Harness
(Mechanical Thermostat)
WHI/BRN from Main Harness
(Electronic Thermostat)
29170 091598
P1642.40
TANk HEATER SWITCH 
FIG. 37 TANK HEATER SWITCH
Location:
 
The tank heater switch is located inside the dis-
penser on the upper right of the whipper motor mount-
ing panel.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the black or white/brown wires from 
the main harness.
3.  With the switch in the “ON” (lower) position check 
for continuity between  the center  and  the  upper 
terminal.  With  the  switch  in  the  “OFF”  (upper) 
position no continuity should be present between 
center and upper terminals.
If continuity is present as described, the heater “ON/OFF” 
switch is operating properly.
If continuity is not present as described, replace the 
switch.
Removal and Replacement:
1.  Refer  to  the  hopper  section  in  this  manual  and 
remove  the  hopper  assemblies  and  the  hopper 
support plate.
2.  Remove the switch mounting nut on the front of 
the front panel.
3.   Remove switch with wires attached from the rear 
of the front panel.
4.  Remove the wires from the switch terminals and 
discard switch.
5.   Connect the wires to the new switch, refer to Fig. 
38.
5.  Push new switch through hole in the front panel 
and secure with face nut.
7.  Refer  to  the  hopper  section  in  this  manual  and 
install  the  hopper  support  plate  and  the  hopper 
assemblies.