Bunn FMD-3 Betriebsanweisung

Seite von 42
37
SERVICE (cont.)
TANk HEATER
FIG. 35 TANK HEATER
P1637.40
Location:
 
The tank heater is located inside the tank and se-
cured to the tank lid.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  With  a  voltmeter,  check  the  voltage  across  the 
black and white wires 120 volt or 240 volt models 
or black and red wires for 120/208 volt  models or 
120/240 volt models. Connect the dispenser to the 
power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models;
 
b) 208 volts ac for three wire 120/208 volt mod-
els.
 
c) 240 volts ac for three wire 120/240 volt models 
and two wire 240 volt models.
 
d) 230 volts ac for two wire 230 volt models.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If  voltage  is  not  present  as  described,  refer  to  the 
dispenser Wiring Diagrams and check the wiring har-
ness.
29170 090407
4.  Disconnect the black wire and the white or red  wire 
from the tank heater terminals.
5.  Check for continuity across the tank heater termi-
nals.
If  continuity  is  present  as  described,  reconnect  the 
wires, the tank heater is operating properly.
If continuity is not present as described, replace the 
tank heater.
NOTE - If the tank heater remains unable to heat, remove 
and inspect heater for cracks in the sheath.
Removal and Replacement:
1.  Shut off water supply to the dispenser.
2.  Disconnect the water supply tube on the tank lid.
3.  Disconnect the black wires on the limit thermo-
stat.
4.  Disconnect the black wire and the white or red wire 
from the tank heater terminals.
5.  Disconnect  the  pink  wire  from  the  liquid  level 
probe.
6.  Disconnect the green wire from the tank.
7.  Remove the thermostat capillary bulb/temperature 
probe by firmly pulling up on the capillary at the 
tank lid. This will disengage the grommet from the 
tank lid.
8.   Remove the ten #8-32 nuts securing the tank lid to 
the tank.
9.  Remove tank lid with limit thermostat, liquid level 
probe and tank heater as an assembly.
10. Remove the two hex nuts securing the tank heater 
to the tank lid. Remove tank heater with gaskets 
and discard.
11. Install new tank heater with gaskets on the tank lid 
and secure with two hex nuts.
12. Install  tank  lid  with  limit  thermostat,  liquid  level 
probe and tank heater on the tank and secure with 
ten #8-32 hex nuts.
13. Connect water inlet line to the tank lid.
14. Reconnect the black wires to limit thermostat,  the 
pink wire to the liquid level probe and the green 
wire to the tank. Refer to the limit thermostat and 
the liquid level board and probe sections in this 
manual when reconnecting wires.
15. Refer to Fig. 36  when reconnecting the wires to 
the tank heater.