Acer 180F1 TK.R5500.043 Benutzerhandbuch

Produktcode
TK.R5500.043
Seite von 20
 
 
Acer AR180 F1 Specifications 
 
Technical Specifications 
Dimensions 
(with bezel) 
438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches) 
 
 
Form factor 
2U rack mount (with cable arms included) 
 
 
 
Weight 
(approximate) 
Maximum 
(All component slots and sockets 
fully populated) 
38 kg (84 lbs.) 
Minimum 
(One HDD, power supply, and 
processor installed) 
27.5 kg (60.6 lbs.)  
 
 
 
BTU rating 
Maximum 
2456.64 BTU/hr.  
 
 
 
System inlet 
temperature 
Operating 
0° - 35°C (50° - 95°F) at sea level with an altitude 
derating of 1°C per 305 m (1.8°F per 1000 ft.) 
above sea level to a maximum of 3050 m (10,000 
ft.) with no direct sustained sunlight. Maximum rate 
of change is 10°C/hr. (18°F/hr.). The upper limit 
depends on the type and number of options 
installed. System performance may be reduced if 
operating with a fan fault or above 30°C (86°F). 
Non-operating 
-40° - 70°C (-40° - 158°F) maximum rate of change 
is 20°C/hr. (36°F/hr.).  
 
 
 
Relative humidity 
(non-
condensing) 
Operating 
8 - 90 % relative humidity (Rh), 28°C (82.4°F) 
maximum wet bulb temperature, non-condensing 
Non-operating 
5 - 95 % relative humidity (Rh), 38.7°C (101.7°F) 
maximum wet bulb temperature, non-condensing 
 
 
 
Emissions 
classification 
(EMC) 
FCC rating 
Class A 
 
Normative standards 
 
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR 
22 Class A  
 
 
 
Power supply 
Rated steady-state power 
720 W (at 100 VAC) 
 
720 W (at 200 VAC) 
Maximum peak power 
720 W (at 100 VAC) 
 
720 W (at 200 VAC)