Acer 180F1 TK.R5500.043 Benutzerhandbuch

Produktcode
TK.R5500.043
Seite von 20
 
 
Acer AR180 F1 Specifications 
 
Expansion slots 
 
The primary I/O bus for the main board is PCIe Gen2. The following table lists the characteristics 
of the PCI-E bus segments. 
 
PCI express Bus Segment Characteristics of PCI Express Topology 
Expansion Slot #  # of 
slots 
Type 
Bus 
Width
1
 
Vol. 
Con. 
Width 
Location  Length 
PCIe 
PCIe Gen 2 
x4 
3.3V 
x8 
Left 
Full height 
PCIe 
PCIe Gen 2 
x8 
3.3V 
x16 
Left 
Full height 
PCIe 
PCIe Gen 2 
x4 
3.3V 
x8 
Right 
Low profile 
PCIe 
PCIe Gen 2 
x8 
3.3V 
x8 
Right 
Low profile 
Acer Flex I/O 
PCIe Gen 2 
x8 
3.3V 
x8 
Left 
 
NOTE: 
1. "Bus Width" refers to the number of physical electrical lanes running to a PCIe® connector. 
2. Default bus assignment (in decimal). Inserting cards with PCI™ bridges may alter the actual bus assignment 
number. 
3. Slots are enumerated differently based on the operating system. Microsoft® operating systems enumerate Device 
ID by bus starting from the lowest bus to the highest.
 
 
 
Storage controllers
  Intel
®
 82801JR (ICH10R) I/O Controller Hub 
 
 
Integrated Serial ATA 
controller 
Simultaneous drive 
transfer channels
 
6 channels 
 
Transfer rate 
synchronous 
(maximum theoretical) 
3 GB/s per channel 
 
Data transfer method 
non-RAID mode 
RAID mode 
 
Drive support 
Serial ATA 
 
Data transfer modes 
Legacy mode 
Combined mode 
 
Protocol 
Serial ATA 
 
Feature 
NCQ (Native Command Queuing) 
AHCI (Advanced Host Controller Interface) 
 
RAID levels supported  0, 1, 5, 10 
 
RAID features 
  Supports multiple logical volumes 
  Supports setup through ROM based array 
configuration utility installation scripting 
NOTE: This controller requires the software RAID driver 
to support hot-plug functions. 
 
RAID OS support 
Windows Server
®
 2008 
Windows Server
®
 2008 R2 
Red Hat
®
 Enterprise Linux 5.3 
Novell
®
 SuSE
®
 Linux Enterprise Server 11