D-Link DFL-1600 Softwarehandbuch

Seite von 213
ReassDoneLinger
How long to remember a completed reassembly (watching for
old dups). (Default: 20)
ReassIllegalLinger
How long to remember an illegal reassembly (watching for
more fragments). (Default: 60)
Note
This object type does not have an identifier and is identified by the name of the type
only. There can only be one instance of this type.
3.55.8. HWMSettings
Description
General settings for Hardware Monitoring
Properties
EnableSensors
Enable/disable all HWM functionality. (Default: No)
SensorPollInterval
Sensor polling interval. (Default: 500)
MemoryPollInterval
Memory polling interval in minutes. (Default: 15)
MemoryUsePercent
Should mem monitor use percentage as unit for monitoring, else it
is megabyte. (Default: Yes)
MemoryLogRepetition
Should we send a log message for each poll result that is in the
Alert, Critical or Warning level, or should we only send when a
new level is reached. (Default: No)
MemoryAlertLevel
Alert log message if free memory is below this value, disable by us-
ing 0. (Default: 0)
MemoryCriticalLevel
Critical log message if free memory is below this value, disable by
using 0. (Default: 0)
MemoryWarningLevel
Warning log message if free memory is below this value, disable by
using 0. (Default: 0)
Note
This object type does not have an identifier and is identified by the name of the type
only. There can only be one instance of this type.
3.55.9. ICMPSettings
Description
Settings related to the ICMP protocol.
Properties
3.55.8. HWMSettings
Chapter 3. Configuration Reference
191