10.5  Logical Printer Settings
Descriptions of Area Mode
The various area modes are described below.
ADAPTED
The data range of the input image is set as the print range. 
Ö
 See
Fig.1
FIXED (HP-GL)
The range that encloses the maximum coordinate of the input
image and the coordinates that represent the starting point of that
coordinate is set as the print range.
FIXED (HP-GL/2)
The range that encloses the maximum coordinate of the input
image and a starting point of (0.0) is set as the print range. 
Ö
 See
Fig.2.
IP AREA
The range specified with the [IP Command] is set as the print
range. 
Ö
 See Fig.3.
IW AREA
The range specified with the [IW Command] is set as the print
range. 
Ö
 See Fig.3.
RASTER
The range that corresponds with the input size specified with the
[Destination Raster] command is set as the print range.
FIRST
Only the first quadrant area is set as the print area. 
Ö
 See Fig.4.
Images located in areas outside of the first quadrant area will not
be printed. 
Ö
 See Fig.5.
Fig.1. (ADAPTED)
Fig.2. (FIXED)
(0,0)
Input image
Output image
Offset
Auto Layout: [NO]
Auto Layout: [YES]
Input image
(+X1,+Y1)
(0,0)
Offset
Output image
Auto Layout: [NO]
Auto Layout: [YES]