Cisco Cisco Packet Data Gateway (PDG) Installationsanleitung

Seite von 317
  Technical Specifications 
Interface Specifications  ▀   
 
ASR 5000 Installation Guide  ▄  
 
   
267 
Central Office Alarm Interface 
The Central Office (CO) alarm interface is a 10-pin Molex connector supporting three dry-contact relay switches. The 
three normally closed (NC) relays can support normally open (NO) or NC devices. The following two figures show the 
pin-out details for this interface and the next figure shows an example CO alarm configuration. 
Table 94. 
SPIO CO Alarms Interface Pinout 
Pin
 
Signal
 
Major Alarm - Normally closed  
Major Alarm - Common  
Major Alarm - Normally open  
Minor Alarm - Normally closed 
Minor Alarm - Common  
Minor Alarm - Normally open 
Critical Alarm - Normally closed 
Critical Alarm - Common  
Critical Alarm - Normally open 
10 
Not used 
 
The 8-foot (2.4 meter) CO alarm cable shipped with the chassis supports redundant SPIO card installations. This “Y” 
cable has two Molex connectors on one end that are keyed to fit into the CO Alarm interfaces in one direction only. 
Each connector mates with one of the side-by-side SPIO cards. On the opposite end is a 9-pin terminal block that you 
can mount to the telco cabinet or equipment rack frame. 
The following figure and table display this cable assembly and its pinouts.