Cisco Cisco Packet Data Gateway (PDG) Installationsanleitung

Seite von 317
Technical Specifications   
▀  Interface Specifications 
 
 
▄  ASR 5000 Installation Guide 
268 
   
Figure 64.  SPIO CO Alarms Cable Assembly 
 
Table 95. 
CO Alarms Cable Pinout 
CO Alarms IF Pin No.
 
Cable Wire Color
 
Cable Terminal Block Position No.
 
Signal
 
Black 
Major Alarm - Normally closed  
Orange 
Major Alarm - Common  
Red 
Major Alarm - Normally open  
Brown 
Minor Alarm - Normally closed 
Yellow 
Minor Alarm - Common  
Green 
Minor Alarm - Normally open 
Blue 
Critical Alarm - Normally closed 
Violet 
Critical Alarm - Common  
Gray 
Critical Alarm - Normally open 
10 
Not wired 
Not equipped 
Not applicable 
 
Electrical Characteristics
 
Each of the three dry-contact relay switches is rated to support a maximum switching current of 1A@30VDC. The relay 