Cisco Cisco Prime Infrastructure 3.0 Installationsanleitung

Seite von 18
7
Scaling for Operations Center
When using Operations Center, we recommend you:
Use the Standard OVA installation option.
Ensure that your network is providing the following performance levels between Operations Center and its managed 
devices:
Bandwidth—250 Kbps 
Latency—up to 5 ms. This is not a hard requirement, but Operations Center will only be as fast as its slowest managed 
instance. The higher the latency, the slower the overall performance. Use the Network Latency column on the 
Operations Center Manage & Monitor Servers page to spot managed instances that may be acting as bottlenecks. 
Ensure all instances managed by Operations Center are running Prime Infrastructure 3.0.
 lists the Operations Center parameters. 
See 
for physical appliance options and 
 for installation option scaling information. For more information, see 
.
Scaling for Data Center
 lists the Data Center parameters. 
1. Compliance is supported on the Professional virtual appliance (OVA) and the Gen 2, UCS-based physical appliance only. It is not supported on: 
Express, Express Plus, or Standard OVAs; OVAs that have been resized to Professional; Gen 1 physical appliances. If you are running Prime 
Infrastructure on an unsupported OVA or physical appliance and want to enable Compliance, you must perform a fresh install of the 3.0 
Professional OVA or Gen2 UCS appliance, then use backup/restore to migrate data from your old server to the new server. See 
 in the 
Cisco Prime Infrastructure 3.0 Administrator Guide
.
2. Changing Clients are wireless users who are roaming across APs or disassociating and associating to APs.
3. The NetFlow rate depends on the number of unique clients in the flows. The supported NetFlow rate is also based on the translated number of 
hourly host records (or unique combinations of server/client and applications) per day. 
Table 4
Scaling Operations Center
Operations Center Parameter
Maximum Supported
Number of managed instances
10
Number of managed virtual domains
100
Concurrent GUI clients
100
Table 5
Scaling Data Center 
Parameter
Standard
Professional
Hardware 
Appliance 
(Gen 2)
Wireless networking
Wireless LAN Controller (WLC)
100
200
400
Data Center networking
Wired Devices (Cisco Catalyst 3000 Series devices, 
Cisco Nexus 5000 Series devices, Cisco Nexus 7000 
Series devices, Cisco Integrated Services Routers 
(ISR), and Cisco ASR devices)
1000
1500
3000