Rolling Back CAD 9.0 to an Earlier Version of CAD
August 4, 2014
133
Rolling Back CAD 9.0 to an Earlier Version of 
CAD
To use the following procedure, you must have backed up your original version of CAD 
before installing CAD 9.0.
To uninstall CAD 9.0 and revert to an earlier version of CAD:
1. If you are rolling back CAD 9.0 on a replicated system, shut down replication 
).
NOTE:  If you do not shut down replication before completing this 
procedure, your CAD services LDAP database will become corrupted.
2. Uninstall CAD 9.0.
3. Install your previous CAD version according to the product documentation.
4. Restore your backed-up data using the CAD Configuration Setup utility:
The configuration data backed up with CDBRTool or DBBackupTool is 
restored by entering the location of the backup file in the Restore Backup 
Data node.
The Recording and Statistics database backed up with BackupDB is 
restored by selecting “Restore From” and entering the location of the 
backup file in the Recording and Statistics Service Database node.
5. If you are rolling back a replicated system, re-establish replication (see 
). 
Rollback Notes
Automated software rollback from CAD 9.0 to a previous version is not 
supported.
If CAD 9.0 is rolled back to a version prior to 8.0, the service releases that 
apply to the earlier version must be reinstalled. For example, if you are rolling 
back from CAD 9.0 to 7.6, any desired CAD 7.6 service releases must be 
reinstalled.
If CAD 9.0 is rolled back to CAD 8.0, the CAD 8.0 Maintenance Releases must 
be reinstalled.