Cisco Cisco Agent Desktop 8.0 Technische Referenzen

Seite von 386
Cisco CAD Error Code Dictionary
4
February 2010
Error
Description
ACDA2000
Text:
Client and BIPPA service have different 
product version.
Type:
Major
Add’l Info:
CTIOS API waitforsingleobject fails.
Action:
Close client browser and restart client.
ACMI1000
Text:
Enterprise Data value is greater than 
maximum size of %d characters, truncating to 
fit.
Type:
Minor
Add’l Info:
None.
Action:
The Enterprise Data that was entered is larger 
than the maximum size for that field. See the 
field that is being set and make sure that any 
time it is set (manually, workflows, etc....) the 
data is less than the maximum.
ACMI2000
Text:
Error occured when validating <%hs> 
message: <%d:%hs> for element <%hs:%d>.
Type:
Error
Add’l Info:
AcmiClient is unable to validate specified 
ACMI message because of problems with 
specified element in the message.
Action:
Verify user entered information is correct. If 
the element is for data obtained from LDAP or 
LRM, verify the services are running and 
active. Verify post install has completed.
ACMI2001
Text:
Error occured when decoding message: %hs 
Msg(%hs) Error (%d:%hs) Element(%hs:%d).
Type:
Major
Add’l Info:
None.
Action:
Error occured when decoding message 
received from the cti server. See error text for 
further details. Verify that the cti server being 
used by CAD is compatible. See CAD install 
doc for compatibility matrix