Firepower System Release Notes for Version 6.0.1 Pre-Install
Installing the Update
Installing the Update
When to Perform the Update
Because the update process may affect traffic inspection, traffic flow, and link state, Cisco strongly recommends you 
perform the update in a maintenance window or at a time when the interruption will have the least impact on your 
deployment.
Installation Method
Use the Firepower Management Center’s web interface to perform the update. Do not install the Version 6.0.1 Pre-install 
on managed devices.
Order of Installation
Update your Firepower Management Centers to Version 6.0.1 Pre-Install and then update the system to Version 6.0.1.
Caution: 
Do not reboot or shut down your appliances during the update until you see the login prompt. The system 
may appear inactive during the pre-checks portion of the update; this is expected behavior and does not require you 
to reboot or shut down your appliances.
After the Installation
There are several additional post-update steps you should take to ensure that your deployment is performing properly. 
These include:
verifying that the update succeeded
making sure that all appliances in your deployment are communicating successfully
After installing the Version 6.0.1 Pre-Install on the Firepower Management Center and reapplying device configuration, 
update the system to Version 6.0.1.
The next sections include detailed instructions not only on performing the update, but also on completing any 
post-update steps. Make sure you complete all of the listed tasks.
Updating the Firepower Management Center
Use the procedure in this section to update your Firepower Management Centers, including virtual Firepower 
Management Centers.
Caution:
 Before you update the Firepower Management Center, reapply access control policies to any managed 
devices. Otherwise, the eventual update of the managed device may fail.
Caution: 
Do not reboot or shut down your appliances during the update until after you see the login prompt. The 
system may appear inactive during the pre-checks portion of the update; this is expected behavior and does not 
require you to reboot or shut down your appliances.
You must install the Pre-Install to your Firepower Management Center prior to updating your system to Version 6.0.1.
1.
Read these release notes and complete any required pre-update tasks.
For more information, see 
.
2.
Download the update from the Support site:
Sourcefire_3D_Defense_Center_S3_6.0.1_Pre-install-6.0.0.999-1.sh
Note:
 Download the update directly from the Support site. If you transfer an update file by email, it may become 
corrupted.
3.
Select System > Updates.
4.
Upload the Pre-Install to the Firepower Management Center by clicking Upload Update.