Cisco Cisco Firepower Management Center 4000

Seite von 42
Version 5.2.0.5
Sourcefire 3D System Release Notes
33
Known Issues
In rare cases, installing Version 5.2 or later on a 3D6500 managed device 
may cause system issues. (129561)
In some cases, the system incorrectly identified SMTP and generated a 
connection event with missing application information if the SMTP server 
responded with a connection error. (130085)
In rare cases, the system may generate critical health alert emails 
containing indecipherable messages. (130518)
In some cases, the system may incorrectly sort values in the Type column or 
omit names from the Security Zones column on the security zones page in 
the object manager. (130569, 130631, 130632)
In some cases, drilling down in a custom workflow may redirect you to the 
incorrect packet view page for an intrusion event. (130620)
In some cases, the system restore boot option does not output to the serial 
port on managed devices even if you selected Physical Serial Port as the 
remote console access option. (130772)
In several places, the documentation incorrectly indicates that you can add 
IP address ranges to network objects. The Sourcefire 3D System currently 
supports adding individual IP addresses or address blocks to network 
objects, not ranges. (130821, 130992)
In some cases, 3D8250, 3D8260, 3D8270, and 3D8290 managed devices 
with 10G or 40G NMSB may experience compatibility issues with 10G 
NFTW NetMods. To be compatible with 10G NFTW Netmods, 10G NMSB 
must be revision 7 or later and 40G NMSB must be revision 8 or later. 
(131189)
In rare cases, the table view of servers (Analysis > Hosts > Servers) may 
duplicate servers and produce inaccurate server counts. (131329)
The eStreamer client omits file policy UUID metadata from type 502 
intrusion events. (131362)
If you schedule multiple simultaneous reporting tasks when using remote 
storage, the system may fail to send all reports to the selected remote 
storage location. As a workaround, schedule report generation tasks in 
30-minute intervals. (131805)
If you modify the interface type on a routed or switched interface 
associated with a hybrid interface, applying the device configuration may 
fail. (132221)
Sourcefire documentation does not reflect that you must disable Spanning 
Tree Protocol (STP) on any third-party switching equipment connected to a 
device’s management interface before connecting to a Series 3 appliance 
using LOM/SOL. (132488)
In some cases, configuring Simple Network Management Protocol (SNMP) 
polling on a Series 3 managed device causes the system to retrieve data 
that is not RFC compliant. (135323)