33
Known Issues
•
In rare cases, installing Version 5.2 or later on a 3D6500 managed device
may cause system issues. (129561)
•
In some cases, the system incorrectly identified SMTP and generated a
connection event with missing application information if the SMTP server
responded with a connection error. (130085)
•
In rare cases, the system may generate critical health alert emails
containing indecipherable messages. (130518)
•
In some cases, the system may incorrectly sort values in the Type column or
omit names from the Security Zones column on the security zones page in
the object manager. (130569, 130631, 130632)
•
In some cases, drilling down in a custom workflow may redirect you to the
incorrect packet view page for an intrusion event. (130620)
•
In some cases, the system restore boot option does not output to the serial
port on managed devices even if you selected Physical Serial Port as the
remote console access option. (130772)
•
In several places, the documentation incorrectly indicates that you can add
IP address ranges to network objects. The Sourcefire 3D System currently
supports adding individual IP addresses or address blocks to network
objects, not ranges. (130821, 130992)
•
In some cases, 3D8250, 3D8260, 3D8270, and 3D8290 managed devices
with 10G or 40G NMSB may experience compatibility issues with 10G
NFTW NetMods. To be compatible with 10G NFTW Netmods, 10G NMSB
must be revision 7 or later and 40G NMSB must be revision 8 or later.
(131189)
•
In rare cases, the table view of servers (Analysis > Hosts > Servers) may
duplicate servers and produce inaccurate server counts. (131329)
•
The eStreamer client omits file policy UUID metadata from type 502
intrusion events. (131362)
•
If you schedule multiple simultaneous reporting tasks when using remote
storage, the system may fail to send all reports to the selected remote
storage location. As a workaround, schedule report generation tasks in
30-minute intervals. (131805)
•
If you modify the interface type on a routed or switched interface
associated with a hybrid interface, applying the device configuration may
fail. (132221)
•
Sourcefire documentation does not reflect that you must disable Spanning
Tree Protocol (STP) on any third-party switching equipment connected to a
device’s management interface before connecting to a Series 3 appliance
using LOM/SOL. (132488)
•
In some cases, configuring Simple Network Management Protocol (SNMP)
polling on a Series 3 managed device causes the system to retrieve data
that is not RFC compliant. (135323)