Setting Up Event Logs   12 - 13
The following trap messages will be sent as they occur: 
n A cold start trap will be sent when the unit first powers up.
n A link up trap is sent when the configuration is changed or restored 
for a severe error condition.
n A link down trap is sent when the configuration is changed or 
encounters a severe error condition.
n A link up trap is sent for an Aironet 340 Series Bridge as soon as the 
radio is configured.
n An authentication failure trap will be sent if an SNMP request is       
n Any normal alarms and logs you have configured to be sent by set-
ting the “loglevel” parameter.        
NOTE:  Since the path to the trap destination may be through a failed or 
not yet established radio link, it is possible that cold start and link down 
traps could be lost.
Use the trapcomm option to specify the community name that will be 
used in the trap message.
The LogLevel option configures The Aironet 340 Series Bridge to gen-
erate enterprise specific traps whenever a log of a given severity or 
higher is produced. The trapdest parameter must be “On”.
The generated trap will contain the text of the log message along with 
the severity of the log. See the MIB definition files for the exact layout 
Enabling Authentication Failure Trap (Authtrap)
Use the authtrap option to control the generation of SNMP authentica-
tion failure traps.