Cisco Cisco Packet Data Gateway (PDG)

Seite von 362
Troubleshooting   
▀  Detecting Faulty Hardware 
 
 
▄  ASR 5500 System Administration Guide, StarOS Release 16 
176 
   
Detecting Faulty Hardware 
When power is applied to the chassis, power is sequentially applied to the Management I/O (MIO) cards, Management 
I/O Universal (UMIO) cards, Data Processing Cards (DPCs), Data Processing Universal Cards (UDPCs), Fabric and 
Storage Cards (FSCs) and System Status Cards (SSCs). 
Each PFU and card installed in the system incorporates light emitting diodes (LEDs) that indicate its operating status. 
This section describes how to use these status LEDs to verify that all of the installed components are functioning 
properly. 
Important:
  As the system progresses through its boot process, some cards will not exhibit immediate LED 
activity. Allow several minutes to elapse after a reboot is initiates before checking the LEDs on the various cards to 
verify that the boot process has successfully completed. 
Licensing Issues 
The system boot process is governed by StarOS licenses. During the startup process, each card performs a series of 
Power-On Self Tests (POSTs) to ensure that the hardware is operational. These tests also verify that the card meets all 
license requirements to operate in this chassis. 
Refer to Chassis, UMIO and UDPC License Requirements in the ASR 5500 Installation Guide for additional 
information on the effect licenses and card types have on the boot process. 
Using the CLI to View Status LEDs 
The status of application and line card LEDs can be viewed through the CLI by entering the show leds all command in 
Exec mode. 
The following displays a sample of this command’s output. 
Slot 01: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 02: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 03: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 05: Run/Fail: Green       | Active:  Green       | Redundant: 
Green         Master:   Green 
Slot 06: Run/Fail: Green       | Active:  Off         | Redundant: 
Green         Master:   Off 
Slot 08: Run/Fail: Green       | Active:  Off         | Redundant: Green 
Slot 11: Run/Fail: Green       | Active:  Green       | Redundant: 
Green         Status:   Green       | Service: Off  
Slot 12: Run/Fail: Green       | Active:  Green       | Redundant: 
Green         Status:   Green       | Service: Off  
Slot 13: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 14: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 15: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 16: Run/Fail: Green       | Active:  Green       | Redundant: Green 
Slot 17: Run/Fail: Green       | Active:  Green       | Redundant: Green