Cisco Cisco Packet Data Gateway (PDG)

Seite von 8994
  Global Configuration Mode Commands (T-threshold phspc) 
threshold dcca-bad-answers  ▀   
 
Command Line Interface Reference, StarOS Release 17  ▄  
 
   
5593 
threshold dcca-bad-answers 
Configures alarm or alert thresholds for invalid or bad responses to the system from Diameter servers. 
Product
 
ACS 
Privilege
 
Security Administrator, Administrator 
Mode
 
Exec > Global Configuration 
configure
 
Entering the above command sequence results in the following prompt: 
[local]host_name(config)# 
Syntax
 
threshold dcca-bad-answers high_thresh [ clear low_thresh ] 
default threshold dcca-bad-answers  
default
 
Disables the threshold for configured alarm and sets the 
high_thresh
 and 
low_thresh
 values to 0. 
high_thresh
 
Default: 0 
Specifies the high threshold number of invalid messages or responses that must be met or exceeded within the 
polling interval to generate an alert or alarm. 
high_thresh
 is an integer from 0 through 1000000. 
clear
 
low_thresh
 
Default: 0 
Specifies the low threshold number of invalid messages/responses that maintains a previously generated 
alarm condition. If the number of failures falls beneath the low threshold within the polling interval, a clear 
alarm will be generated. 
low_thresh
 is an integer from 0 through 1000000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage 
In the event that the system receives invalid message or response from Diameter server dcca-bad-answers is 
generated. 
DCCA bad answer messages size threshold generates alerts or alarms based on the number of invalid 
response or messages received during the specified polling interval. 
Alerts or alarms are triggered for DCCA bad answers based on the following rules: