Cisco Cisco Packet Data Gateway (PDG)

Seite von 655
VPC-DI Changes in Release 17   
▀  VPC-DI Feature Changes for 17.1 
 
 
▄  Release Change Reference, StarOS Release 17 
648 
   
CSCuq95642 - [QvPC-DI] unable to start GTPUMgr, insufficient unserved 
memory 
Applicable Products: VPC-DI 
Feature Changes 
Starting QvPC-DI VMs with Insufficient Memory
 
vzulkows 
Previous Behavior: All VPC-DI VMs were treated the same. 
New Behavior: VPC-DI VMs with memory less than 48GB are treated as reduced capacity (Medium Model) systems. 
CSCuq97176 - QvPC-DI Network mapping and A-B bonding support 
Applicable Products: VPC-DI 
Feature Changes 
Network Mapping of NICs for non-UCS Hardware
 
VPC-DI now supports a way to specify network topology in a param.cfg file that specifies NIC operating parameters 
including: 
 
Designation of DI-Network or service ports 
 
VLAN for DI-Network  
 
Configuration applies to single NIC or a pair of NICs in A-B redundancy mode 
A-B network redundancy (bonding driver) is supported for non-UCS hardware. This feature allows for setup of 
redundant connections to the physical L2 switch.  
The following are sample bonding configurations: 
qvpc-di:card3-cpu0# cat /cdrom1/staros_param.cfg  
CARDSLOT=3 
  
ETH0_MAC=00:05:47:00:02:01 
ETH1_MAC=00:50:56:87:d7:1d 
ETH2_MAC=00:50:56:87:a2:52 
  
BOND0_MAP=ETH0