Cisco Cisco Packet Data Gateway (PDG)
VPC-DI Changes in Release 17
▀ VPC-DI Feature Changes for 17.1
▄ Release Change Reference, StarOS Release 17
648
CSCuq95642 - [QvPC-DI] unable to start GTPUMgr, insufficient unserved
memory
Applicable Products: VPC-DI
Feature Changes
Starting QvPC-DI VMs with Insufficient Memory
vzulkows
Previous Behavior: All VPC-DI VMs were treated the same.
New Behavior: VPC-DI VMs with memory less than 48GB are treated as reduced capacity (Medium Model) systems.
CSCuq97176 - QvPC-DI Network mapping and A-B bonding support
Applicable Products: VPC-DI
Feature Changes
Network Mapping of NICs for non-UCS Hardware
VPC-DI now supports a way to specify network topology in a param.cfg file that specifies NIC operating parameters
including:
including:
Designation of DI-Network or service ports
VLAN for DI-Network
Configuration applies to single NIC or a pair of NICs in A-B redundancy mode
A-B network redundancy (bonding driver) is supported for non-UCS hardware. This feature allows for setup of
redundant connections to the physical L2 switch.
redundant connections to the physical L2 switch.
The following are sample bonding configurations:
qvpc-di:card3-cpu0# cat /cdrom1/staros_param.cfg
CARDSLOT=3
ETH0_MAC=00:05:47:00:02:01
ETH1_MAC=00:50:56:87:d7:1d
ETH2_MAC=00:50:56:87:a2:52
BOND0_MAP=ETH0