  VPC-DI Changes in Release 17 
VPC-DI Feature Changes for 17.1  ▀   
 
Release Change Reference, StarOS Release 17  ▄  
 
   
649 
BOND0_PRIMARY=ETH0 
BOND0_REVERSION_POLICY=0 
BOND0_LINK_DETECT=0 
BOND0_MII_POLL=100 
  
BOND1_MAP=ETH1,ETH2 
BOND1_PRIMARY=ETH1 
BOND1_REVERSION_POLICY=0 
BOND1_LINK_DETECT=0 
BOND1_MII_POLL=100 
CSCuq97178 - Should be able to boot SF locally even with passthrough NICs 
Applicable Products: VPC-DI 
Feature Changes 
Passthrough Booting Locally
 
For a CF, if the network interface is configured and a slot number is available, the CF will try to boot from the other CF 
first. It tries boots based on its boot.sys if the CF fails to boot from the other CF (current behavior). 
If the network interface is not configured or a slot number is not available, the CF will boot based on its boot.sys 
without trying to boot from the other CF. This is the scenario for passthrough NIC. 
For an SF, if the network interface is configured and a slot number is available, the SF will boot from either of the CFs 
(current behavior) 
If the network interface is not configured or a slot number is unavailable, the SF will boot from its local partition 1 to 
load “/boot1/staros.bin”. This is the scenario for passthrough NIC. 
CSCur44411 - DI: rc should reboot if masterslot can't be determined 
Applicable Products: VPC-DI 
Feature Changes 
SF Reboot Timeout When CF Cannot Be Detected
 