2.1.6.7  Autodiscovery 
ONS 15327 autodiscovery is identical to ONS 15454 SONET autodiscovery, described in 
. 
2.1.7  ONS 15454 SDH 
 for the ONS 15454 SDH software releases 
that Prime Optical 10.3 supports. 
2.1.7.1  Shelves 
All supported ONS 15454 SDH NEs have exactly one shelf each, with the exception of the ONS 
15454 SDH multiservice transport platform (MSTP) R7.0, which can have up to eight shelves 
per NE. 
2.1.7.2  Slots 
The ONS 15454 SDH has one shelf view supplemented with the top subrack Electrical Facility 
Connection Assembly (EFCA) shelf and bottom subrack chassis. The main shelf has 17 slots 
numbered 1 to 17 and contains cards that carry traffic. The EFCA shelf has 12 additional slots 
numbered 18 to 29 and contains Front Mount Electrical Connection (FMEC) modules, the 
ALM/PWR/MIC (A/P/M) module, and the CRFT/TMG/MIC (C/T/M) module. The Timing 
Communications and Control-International (TCC-I) module must be in slot 7 or slot 11, the 
A/P/M module must be in slot 23, and the C/T/M module must be in slot 24. 
2.1.7.3  Equipment 
All cards in the ONS 15454 SDH R5.0 and later display administration and service states. For 
earlier software releases, these states are not applicable and Prime Optical displays them as N/A. 
2.1.7.3.1 
Equipment Administration State 
The attribute name is ACTUAL_EQUIPMENT_SERVICE_STATE and is displayed in 
getAdditionalInfo for the equipment. 
 lists the attribute values for the administration 
state. 
list the attribute values for the service state. 
Table 2-7: Equipment Administration State (ONS 15454 SDH) 
Attribute Value
 
Meaning
 
In Service
 
Places the entity In Service.
 
Auto in Service
 
Places the entity in Auto in Service. The circuit is out of service until it 
receives a valid signal for the duration of the soak period, at which time 
the circuit state changes to In Service. During the soak period, alarms 
and loopbacks are suppressed but traffic is carried. 
 
Out of Service–Maintenance
 
Removes the entity from service for maintenance. Alarms are no longer 
generated.
 
Out of Service
 
Removes the entity from service and disables it. Alarms are no longer 
generated and traffic is not carried.