Cisco Headend Digital Broadband Delivery System Installationsanleitung
Set Up the BFS
78-4004034-01 Rev C
41
5 In the Available Sources field, click to select SAIXOD_IB_SM and click Add.
The selection moves to the Selected Sources field.
6 In the Available Sources field, click to select SAIXOD_IB_LG and click Add.
The selection moves to the Selected Sources field.
7 In the Available Sources field, click to select SAIXOD_OOB and click Add. The
selection moves to the Selected Sources field.
8 Click Save. The system saves the server information in the DNCS database and
closes the Authorize BFS Server window. The Servers tab on the BFS
Administration window updates to include the new server.
9 Click File and select Close to close the BFS Administration window.
10 Your next step is to restart the OSM process. Go to
10 Your next step is to restart the OSM process. Go to
Restarting the OSM Process
(on page 41).
Restarting the OSM Process
After you authorize the BFS servers, use the dncsControl utility to restart the OSM
process on the DNCS.
Follow these instructions to restart the OSM process.
1 In an xterm window on the DNCS, type dncsControl and then press Enter. The
Follow these instructions to restart the OSM process.
1 In an xterm window on the DNCS, type dncsControl and then press Enter. The
Dncs Control window opens.
2 Type 2 (for Startup / Shutdown Single Element Group) and then press Enter.
The Dncs Control window updates to list all of the DNCS processes and servers.
3 Type the number associated with the DNCS HCT Manager & OSM element
group and then press Enter. A message appears that prompts the user to enter
the target status for the entire element group or to type e to display each
individual element.
4 Type e and then press Enter. The Dncs Control window updates to list the
individual elements that comprise the DNCS HCT Manager & OSM element
group.
5 Type the number associated with /dvs/dncs/bin/osm and then press Enter. A
message appears that prompts the user to enter the target status for the selected
element.
6 Type 2 (for running) and then press Enter. A confirmation message appears.
7 Type y (for yes) and then press Enter. The Dncs Control window updates to
7 Type y (for yes) and then press Enter. The Dncs Control window updates to
reflect the current status of each element in the group.
8 Wait until the current state (Curr Stt) of the /dvs/dncs/bin/osm element is
running.
Note: The Dncs Control window updates automatically in about 30 seconds or
Note: The Dncs Control window updates automatically in about 30 seconds or
you can press Enter to force an update.