Cisco Compact Mini Amp Models 93191 & 93198 862 MHz with 42 54 MHz Split Installationsanleitung
2-12
Installing and Configuring the GainMaker Line Extender
593057 Rev E
Installing the Power Supply,
Continued
2.
Set the AC Undervoltage Lockout Selector for your powering application as
illustrated in the following diagram.
illustrated in the following diagram.
T7312
Jumper Position for
50V Undervoltage
Lockout
Jumper Position for
30V Undervoltage
Lockout
Jumper Position for
40V Undervoltage
Lockout
Note: The AC Undervoltage Lockout Selector positions are also noted on the
power supply.
power supply.
3. Proceed