Cisco Cisco 1 GHz GainStar Amplifier Installationsanleitung

Seite von 80
 
Attaching the Coaxial Connectors 
 
 
To Connect the RF Connector Pin 
Complete the following steps to connect the RF connector pin to the GainStar Line 
Extender housing. 
1  Begin this procedure with the GainStar Line Extender housing open. 
2  If the center conductor pin extends beyond the STRIP line on the housing, trim 
the pin with heavy-duty wire cutters. 
3  If the RF connector is PG11, go to Step 4. If the RF connector is 5/8”, screw the 
RF cable connector adapter onto the housing before proceeding to Step 4. 
4  Insert the appropriate RF connector into the desired RF port. Tighten the 
connector nut according to the manufacturer specifications. 
5  Tighten the RF F-Cable connector bolt from 0.9 Nm to 1.0 Nm. 
6  Repeat steps 2 through 4 for each RF port used. 
7  Check for the presence of RF at unused port. 
a  If RF is present, insert a 75 Ohm terminator into the port and tighten per 
manufacturer specifications. 
b  If RF is not present, insert a housing plug into the port and tighten from 6.8 
Nm to 9.0 Nm. 
8  Proceed to 
Installing the Housing
 
OL-31945-02 
15