Installing the Housing 
Installing the Housing 
To Install the Housing on a Strand (Aerial) 
Complete the following steps to install the housing on a strand (aerial). The housing 
does not need to be opened for strand installation. 
Important: The minimum strand diameter should be 5/16 inch. 
    CAUTION: 
Be aware of the size and weight of the housing while strand 
mounting. Ensure that the strand can safely support the weight of 
the housing. 
1  Loosen the strand clamp bolts. 
2  Lift the housing to the proper position on the strand. 
3  Slip the strand clamps over the strand and finger-tighten the clamp bolts. This 
allows additional movement of the housing as needed. 
4  Move the housing as needed to install the coaxial cable and connectors. See the 
diagram below. 
 
5  Using a ½-inch torque wrench, tighten the strand clamp bolts from 6.8 Nm to 9.0 
Nm. Make sure there is good mechanical contact between the strand and the 
housing. 
Note: A slight tilt of the housing face is normal. Cable tension will cause the 
housing to hang more closely to vertical. 
6  Connect the coaxial cable to the pin connector according to connector 
manufacturer specifications. 
7  Proceed to 
Installing the Accessories
 
OL-31945-02 