Cisco Cisco 1 GHz GainStar Amplifier Installationsanleitung
Attaching the Coaxial Connectors
To Connect the RF Connector Pin
Complete the following steps to connect the RF connector pin to the GainStar Line
Extender housing.
1 Begin this procedure with the GainStar Line Extender housing open.
2 If the center conductor pin extends beyond the STRIP line on the housing, trim
1 Begin this procedure with the GainStar Line Extender housing open.
2 If the center conductor pin extends beyond the STRIP line on the housing, trim
the pin with heavy-duty wire cutters.
3 If the RF connector is PG11, go to Step 4. If the RF connector is 5/8”, screw the
RF cable connector adapter onto the housing before proceeding to Step 4.
4 Insert the appropriate RF connector into the desired RF port. Tighten the
connector nut according to the manufacturer specifications.
5 Tighten the RF F-Cable connector bolt from 0.9 Nm to 1.0 Nm.
6 Repeat steps 2 through 4 for each RF port used.
7 Check for the presence of RF at unused port.
6 Repeat steps 2 through 4 for each RF port used.
7 Check for the presence of RF at unused port.
a If RF is present, insert a 75 Ohm terminator into the port and tighten per
manufacturer specifications.
b If RF is not present, insert a housing plug into the port and tighten from 6.8
Nm to 9.0 Nm.
8 Proceed to
Installing the Housing.
OL-31945-02
15