Cisco Cisco UCS B200 M2 Blade Server Datenbogen

Seite von 70
Cisco UCS B420 M3 Blade Server
18
CONFIGURING the SERVER
“Adapter 1,” “Adapter 2,” and “Adapter 3” refer to the UCSM naming convention for the 
adapter slots (this document uses the UCSM naming convention). In the server BIOS and on the 
motherboard, the corresponding slots are labeled as “mLOM,” “Mezz 1,” and “Mezz 2,” 
respectively. See 
Supported Configurations
(1) 4-CPU System Configuration
Select an adapter combination in accordance with 
Cisco UCS Storage Accelerators
1
UCSB-F-FIO-1600MS
UCS 1600 GB Fusion ioMemory3 SX Scale line for B-Series
UCSB-F-FIO-1300MP
UCS 1300 GB Fusion ioMemory3 PX Performance line for B-Series
UCSB-F-FIO-785M
Cisco UCS 785 GB MLC Fusion ioDrive2
UCSB-F-FIO-365M 
Cisco UCS 365 GB MLC Fusion ioDrive2
UCSB-F-LSI-400S
LSI 400 GB SLC WarpDrive
Notes
1. Do not mix Fusion io storage accelerator families. That is, do not mix “MP” or “MS” (ioMemory3) with “M” 
(ioDrive2) family cards.
Table 9
  Adapter Slot Naming
Server BIOS and Motherboard Slot Naming
UCSM Slot Naming
mLOM (VIC 1240 only)
Adapter 1
Mezz1
Adapter 2
Mezz2
Adapter 3
Table 10  Supported Adapter
1
 Combinations (4-CPU Configuration)  
Adapter Slot 1 Adapter Slot 2
Adapter Slot 3
Total Available Bandwidth
2 x 2208 XP
2 x 2204 XP
2 x 2104 XP
VIC 1240
Not populated
Not populated
40 Gb
20 Gb
20 Gb
VIC 1240
Not populated
VIC 1280
120 Gb
60 Gb
40 Gb
Not populated Not populated
VIC 1280
80 Gb
40 Gb
20 Gb
VIC 1240
Not populated
Emulex or QLogic
 
adapter
60 Gb
40 Gb
40 Gb
Table 8   Supported Adapters (continued)
Product ID (PID)