4.8  Install the Front Fan Spacers for the Fixed Hard Drive Bay 
Install the Front Fan Spacers for systems with a standard fixed hard drive bay cage. The 
following instructions do not apply to systems with a hot-swappable hard drive bay cage. Use 
four screws to attach the four plastic spacers to the unlabeled side of the Front Fan. Insert 
screw (letter B in the following figure) from the inside of the Front Fan to secure the plastic 
spacer (letter A in the figure). Hold the screw steady with your thumb while using a hex driver 
(letter C in figure) to secure the plastic spacer to the screw. 
 
TP00573
B
C
A
 
Figure 20. Installing Front spacers for the Fixed Hard Drive Bay 
1.  Insert the Front Fan into the hard drive bay cage. Make sure that the Front Fan 
cable is positioned at the bottom of the cage. Make sure that the airflow is towards 
the server board. This means that the label should face to the inside of the hard 
drive bay cage (towards the server board). The plastic spacers should be facing 
towards the front grill of the hard drive bay cage. 
 
TP00571
 
Figure 21. Reinstalling Fan with Front spacers to the Fixed Hard Drive Bay