Cabinet mount
If installing the oven in a built-in cabinet, the cabinet must have its plastic surfaces 
and adhesive parts resistant up to 90 °C, and adjacent furniture must be resistant 
up to 75 °C. Samsung is not responsible for damage to furniture from the oven’s 
heat emission.
The oven must be properly ventilated. For ventilation, leave a gap of about 50 mm 
between the lower shelf of the cabinet and the supporting wall. If you install the 
oven under a cooktop, follow the cooktop’s installation instructions.
Required Dimensions for Installation
D
E
C
B
A
L
K
J
I
F
H
G
Oven (mm)
A
560
G
Max. 506
B
175
H
Max. 494
C
370
I
21
D
Max. 50
J
545
E
595
K
572
F
595
L
550
D
C
B
A
E
Built-in cabinet (mm)
A
Min. 550
B
Min. 560
C
Min. 50
D
Min. 590 - Max. 600
E
Min 460 x Min. 50
NOTE
The built-in cabinet must have vents (E) to 
ventilate heat and circulate the air.
D
C
B
A
Under-sink cabinet (mm)
A
Min. 550
B
Min. 560
C
Min. 600
D
Min 460 x Min. 50
NOTE
The built-in cabinet must have vents (D) to 
ventilate heat and circulate the air.