HP laserjet 3390, 3392 all-in-one Servicehandbuch

Seite von 368
Table 6-2
  Critical-error messages
Control-panel message
Description
Recommended action
Scanner error # Turn off then on
The scanner assembly has experienced an
internal error.
1 = dark find
2 = LMW temp find
3 = bulb warm up from off
4 = bulb warm up from coarse
5 = cal label find
6 = doc original find
7 = LMW final find
8 = cal label find after scan
9 = cal label find prior to standby
10 = doc original find prior to standby
11 = bulb warm up from standby
Turn the all-in-on off, and then on.
If the error persists, replace the scanner
assembly. See 
If the error persists, replace the formatter.
See 
.
49 Error
The all-in-one has experienced an internal
embedded software error.
Turn off the power by using the power switch,
wait at least 30 seconds, and then turn on the
power and wait for the all-in-one to initialize.
50.x Fuser Error
The all-in-one has experienced an internal
hardware error.
1.
Turn off the power by using the power
switch, and then wait at least 30
seconds.
2.
If a surge protector is being used,
remove it. Plug the all-in-one directly
into the electrical outlet.
3.
Turn on the power and wait for the all-in-
one to initialize.
51 Laser Error
The all-in-one has experienced an internal
hardware error.
Turn off the power by using the power switch,
wait at least 30 seconds, and then turn on the
power and wait for the all-in-one to initialize.
If a surge protector is being used, remove it.
Plug the all-in-one directly into the electrical
outlet. Use the power switch to turn the all-in-
one on.
52 Scanner Error
The all-in-one has experienced an internal
hardware error.
Turn off the power by using the power switch,
wait at least 30 seconds, and then turn on the
power and wait for the all-in-one to initialize.
If a surge protector is being used, remove it.
Plug the all-in-one directly into the electrical
outlet. Use the power switch to turn the all-in-
one on.
55.1 Error
The all-in-one has experienced an internal
hardware error.
Turn off the power by using the power switch,
wait at least 30 seconds, and then turn on the
power and wait for the all-in-one to initialize.
ENWW
Control-panel messages
213